{"id":15096,"date":"2016-02-01T15:36:04","date_gmt":"2016-02-01T13:36:04","guid":{"rendered":"https:\/\/bgr.bg\/shop\/air-cooled-chiller-clint-cha-k-91%c3%b7151\/"},"modified":"2026-01-05T08:55:32","modified_gmt":"2026-01-05T06:55:32","slug":"air-cooled-chillers-clint-chak-91-151","status":"publish","type":"product","link":"https:\/\/bgr.bg\/en\/store-en\/chillers\/air-cooled-liquid-chillers\/air-cooled-chillers-clint-chak-91-151\/","title":{"rendered":"Air-cooled chiller CLINT, CHA\/IK\/\u0410 91\u00f7151"},"content":{"rendered":"<div class=\"description\">\n<h2>Main advantages of the chiller:<\/h2>\n<p><span class=\"tooltip tooltip-txt\" data-tooltip=\"Heating \/ Cooling \" data-position=\"top\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-5299\" title=\"Heating \/ Cooling\" src=\"http:\/\/bgr.bg\/wp-content\/uploads\/2016\/12\/heating-cooling.png\" alt=\"Air cooled chillers Clint\" width=\"35\" height=\"35\"><\/span>\n<span class=\"tooltip tooltip-txt\" data-tooltip=\"Spiral compressor\" data-position=\"top\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-5300\" title=\"Spiral compressor\" src=\"http:\/\/bgr.bg\/wp-content\/uploads\/2016\/12\/scroll.png\" alt=\"Air cooled chillers Clint\" width=\"35\" height=\"35\"><\/span>\n<span class=\"tooltip tooltip-txt\" data-tooltip=\"Axial Fan\" data-position=\"top\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3583\" title=\"Axial Fan\" src=\"http:\/\/bgr.bg\/wp-content\/uploads\/2016\/11\/axial.png\" alt=\"Air cooled chillers Clint\" width=\"34\" height=\"34\"><\/span>\n<span class=\"tooltip tooltip-txt\" data-tooltip=\"Plastic heat exchanger\" data-position=\"top\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3585 size-full\" title=\"Plastic heat exchanger\" src=\"http:\/\/bgr.bg\/wp-content\/uploads\/2016\/11\/plastinchat-toploobm.gif\" alt=\"Air cooled chillers Clint\" width=\"35\" height=\"34\"><\/span>\n<span class=\"tooltip tooltip-txt\" data-tooltip=\"Class A\" data-position=\"top\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-5281\" title=\"Class A\" src=\"http:\/\/bgr.bg\/wp-content\/uploads\/2016\/12\/a-class.png\" alt=\"Air cooled chillers Clint\" width=\"34\" height=\"34\"><\/span>\n<span class=\"tooltip tooltip-txt\" data-tooltip=\"R410A\" data-position=\"top\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-5268\" title=\"R410A\" src=\"http:\/\/bgr.bg\/wp-content\/uploads\/2016\/12\/r410a.png\" alt=\"Air cooled chillers Clint\" width=\"34\" height=\"34\"><\/span>\n<\/p>\n<h2 style=\"text-align: justify;\">Chillers and heat pumps of the CHA\/IK\/A 91\u00f7151 AQUAPLUS series<\/h2>\n<p style=\"text-align: justify;\">Water-cooled chillers and heat pumps of the CHA\/IK\/A 91\u00f7151 series, with refrigerant R410A, are designed to meet the needs of small and medium-sized domestic and service sector environments. With a peraluminum structure resistant to corrosion over time, these machines can be combined with fan convectors or with intermediate heat exchangers for industrial applications. All machines have energy efficiency class A and are equipped with inverter control of the Scroll compressor for better efficiency at partial loads (SEER\/IPLV\/SCOP). The Microchannel condenser, available in a special version, provides even higher efficiency (high EER) with better heat exchange than traditional heat exchangers. A wide range of accessories, factory-fitted or supplied separately, complement the exceptional flexibility and functionality of the series.<\/p>\n<p style=\"text-align: justify;\">The heat pump version is designed to produce water up to 60\u00b0C. The machines comply with the ErP Regulation.<\/p>\n<p style=\"text-align: justify;\">On request, machines are supplied with R452B or R454B refrigerant.<\/p>\n<h3>Main advantages of chillers and heat pumps of the CHA\/IK\/\u0410 91\u00f7151 AQUAPLUS series:<\/h3>\n<\/div>\n<ul>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">Construction with supporting frame, peraluminum, galvanized sheet.<\/div>\n<\/li>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">DC Inverter scroll compressor with oil sight glass, internal overheating protection and crankcase heater.<\/div>\n<\/li>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">Axial fans, low-noise, with a special profile of the fan wing, directly coupled to the external rotor of the motor<\/div>\n<\/li>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">Condenser of copper tubes, finned with aluminum lamellae or MICROCHANNEL.<\/div>\n<\/li>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">Evaporator made of AISI 316 stainless steel (spliced type), equipped with differential pressure switch and antifreeze heater. On heat pump models, an antifreeze heater is always installed.<\/div>\n<\/li>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">Electronic thermostatic valve.<\/div>\n<\/li>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">Refrigerant R410A. On request \u2013 refrigerant R452B or R454B.<\/div>\n<\/li>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">The electrical panel includes: main switch with automatic door locking, fuses, compressor and pump protection.<\/div>\n<\/li>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">Condensation control is included: an electronic proportional device which ensures efficient, continuous operation of the machine at outside air temperatures up to &#8211; 20\u00b0C in cooling mode. In addition, it allows to reduce the noise level, especially at night. It consists of a fan speed regulator with continuous speed control and high and low pressure transducers of the cooling circuit.<\/div>\n<\/li>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">It operates in heating mode with an outside air temperature of up to -15\u00b0C.<\/div>\n<\/li>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">The water circuit includes: differential water pressure switch, high-efficiency EC pump, safety valve, expansion tank.<\/div>\n<\/li>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">Microprocessor control and regulation system.<\/div>\n<\/li>\n<li style=\"text-align: justify;\">\n<div class=\"leftAlign\">Advanced functions: remote set point with 0-10V signal, remote set point with 4-20 mA signal, remote signal to activate second set point, digital input demand limit, hybrid systems control, domestic hot water production control.<\/div>\n<\/li>\n<\/ul>\n<h3>Technical data<\/h3>\n<table class=\"tableStyle\">\n<tbody>\n<tr>\n<td colspan=\"3\">CHA\/K<\/td>\n<td>91<\/td>\n<td>101<\/td>\n<td>131<\/td>\n<td>151<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Cool STD version<\/td>\n<td>Cooling capacity (1)<\/td>\n<td>kW<\/td>\n<td>25.8<\/td>\n<td>30.5<\/td>\n<td>35.9<\/td>\n<td>42.3<\/td>\n<\/tr>\n<tr>\n<td>Energy consumed (1)<\/td>\n<td>kW<\/td>\n<td>8<\/td>\n<td>9.5<\/td>\n<td>11.3<\/td>\n<td>13.4<\/td>\n<\/tr>\n<tr>\n<td>EER (1)<\/td>\n<td><\/td>\n<td>3.23<\/td>\n<td>3.21<\/td>\n<td>3.18<\/td>\n<td>3.16<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">Cooling STD version &#8211; (EN 14511)<\/td>\n<td>Cooling capacity (1)<\/td>\n<td>kW<\/td>\n<td>25.6<\/td>\n<td>30.3<\/td>\n<td>35.7<\/td>\n<td>42.1<\/td>\n<\/tr>\n<tr>\n<td>Energy consumed (1)<\/td>\n<td>kW<\/td>\n<td>8.1<\/td>\n<td>9.7<\/td>\n<td>11.5<\/td>\n<td>13.6<\/td>\n<\/tr>\n<tr>\n<td>EER (1)<\/td>\n<td><\/td>\n<td>3.16<\/td>\n<td>3.12<\/td>\n<td>3.1<\/td>\n<td>3.1<\/td>\n<\/tr>\n<tr>\n<td>ESEER (1)<\/td>\n<td><\/td>\n<td>4.57<\/td>\n<td>4.31<\/td>\n<td>4.31<\/td>\n<td>4.27<\/td>\n<\/tr>\n<tr>\n<td>EUROVENT Class<\/td>\n<td><\/td>\n<td>A<\/td>\n<td>A<\/td>\n<td>A<\/td>\n<td>A<\/td>\n<\/tr>\n<tr>\n<td>SEER(2)<\/td>\n<td><\/td>\n<td>4.42<\/td>\n<td>4.16<\/td>\n<td>4.21<\/td>\n<td>4.22<\/td>\n<\/tr>\n<tr>\n<td>Energy efficiency (2)<\/td>\n<td>%<\/td>\n<td>174<\/td>\n<td>163<\/td>\n<td>165<\/td>\n<td>166<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Cooling MC version<\/td>\n<td>Cooling capacity (1)<\/td>\n<td>kW<\/td>\n<td>25.8<\/td>\n<td>30.5<\/td>\n<td>35.9<\/td>\n<td>42.3<\/td>\n<\/tr>\n<tr>\n<td>Energy consumed (1)<\/td>\n<td>kW<\/td>\n<td>7.9<\/td>\n<td>9.4<\/td>\n<td>11.2<\/td>\n<td>13.3<\/td>\n<\/tr>\n<tr>\n<td>EER (1)<\/td>\n<td><\/td>\n<td>3.27<\/td>\n<td>3.24<\/td>\n<td>3.21<\/td>\n<td>3.18<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">Cooling MC version &#8211; (EN 14511)<\/td>\n<td>Cooling capacity (1)<\/td>\n<td>kW<\/td>\n<td>25.6<\/td>\n<td>30.3<\/td>\n<td>35.7<\/td>\n<td>42.1<\/td>\n<\/tr>\n<tr>\n<td>Energy consumed (1)<\/td>\n<td>kW<\/td>\n<td>8<\/td>\n<td>9.6<\/td>\n<td>11.4<\/td>\n<td>13.5<\/td>\n<\/tr>\n<tr>\n<td>EER (1)<\/td>\n<td><\/td>\n<td>3.2<\/td>\n<td>3.16<\/td>\n<td>3.13<\/td>\n<td>3.12<\/td>\n<\/tr>\n<tr>\n<td>ESEER (1)<\/td>\n<td><\/td>\n<td>4.63<\/td>\n<td>4.36<\/td>\n<td>4.36<\/td>\n<td>4.32<\/td>\n<\/tr>\n<tr>\n<td>EUROVENT Class<\/td>\n<td><\/td>\n<td>A<\/td>\n<td>A<\/td>\n<td>A<\/td>\n<td>A<\/td>\n<\/tr>\n<tr>\n<td>SEER(2)<\/td>\n<td><\/td>\n<td>4.48<\/td>\n<td>4.21<\/td>\n<td>4.26<\/td>\n<td>4.27<\/td>\n<\/tr>\n<tr>\n<td>Energy efficiency (2)<\/td>\n<td>%<\/td>\n<td>176<\/td>\n<td>165<\/td>\n<td>167<\/td>\n<td>168<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Heating STD version<\/td>\n<td>Cooling capacity (3)<\/td>\n<td>kW<\/td>\n<td>28.7<\/td>\n<td>34.3<\/td>\n<td>40.4<\/td>\n<td>48<\/td>\n<\/tr>\n<tr>\n<td>Energy consumed (3)<\/td>\n<td>kW<\/td>\n<td>8.1<\/td>\n<td>9.9<\/td>\n<td>11.8<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>COP (3)<\/td>\n<td><\/td>\n<td>3.54<\/td>\n<td>3.46<\/td>\n<td>3.42<\/td>\n<td>3.43<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">Heating STD version (EN 14511)<\/td>\n<td>Heating capacity (3)<\/td>\n<td>kW<\/td>\n<td>28.9<\/td>\n<td>34.5<\/td>\n<td>40.7<\/td>\n<td>48.3<\/td>\n<\/tr>\n<tr>\n<td>Energy consumed (3)<\/td>\n<td>kW<\/td>\n<td>8.3<\/td>\n<td>10.1<\/td>\n<td>12<\/td>\n<td>14.3<\/td>\n<\/tr>\n<tr>\n<td>COP (3)<\/td>\n<td><\/td>\n<td>3.48<\/td>\n<td>3.42<\/td>\n<td>3.39<\/td>\n<td>3.38<\/td>\n<\/tr>\n<tr>\n<td>EUROVENT Class<\/td>\n<td><\/td>\n<td>A<\/td>\n<td>A<\/td>\n<td>A<\/td>\n<td>A<\/td>\n<\/tr>\n<tr>\n<td>SCOP(4)<\/td>\n<td><\/td>\n<td>3.34<\/td>\n<td>3.23<\/td>\n<td>3.33<\/td>\n<td>3.41<\/td>\n<\/tr>\n<tr>\n<td>Energy efficiency(4)<\/td>\n<td>%<\/td>\n<td>131<\/td>\n<td>126<\/td>\n<td>130<\/td>\n<td>133<\/td>\n<\/tr>\n<tr>\n<td>Energy Class (4)<\/td>\n<td><\/td>\n<td>A+<\/td>\n<td>A+<\/td>\n<td>A+<\/td>\n<td>A+<\/td>\n<\/tr>\n<tr>\n<td>Compressor<\/td>\n<td>Number<\/td>\n<td>n\u00b0<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Evaporator<\/td>\n<td>Water flow<\/td>\n<td>l\/s<\/td>\n<td>1.23<\/td>\n<td>1.46<\/td>\n<td>1.72<\/td>\n<td>2.02<\/td>\n<\/tr>\n<tr>\n<td>Loss of pressure<\/td>\n<td>kPa<\/td>\n<td>20<\/td>\n<td>29<\/td>\n<td>31<\/td>\n<td>31<\/td>\n<\/tr>\n<tr>\n<td>Pipe connection<\/td>\n<td>&#8220;G<\/td>\n<td>1 1\/4&#8243;<\/td>\n<td>1 1\/4&#8243;<\/td>\n<td>1 1\/4&#8243;<\/td>\n<td>1 1\/4&#8243;<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\"> Electrical characteristics<\/td>\n<td>Power supply<\/td>\n<td> V\/Ph\/Hz<\/td>\n<td colspan=\"4\">400\/3+N\/50<\/td>\n<\/tr>\n<tr>\n<td>Max. Operating current<\/td>\n<td> A<\/td>\n<td>21<\/td>\n<td>24<\/td>\n<td>27<\/td>\n<td>34<\/td>\n<\/tr>\n<tr>\n<td>Max. Starting current<\/td>\n<td> A<\/td>\n<td>11<\/td>\n<td>14<\/td>\n<td>15<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Water circle<\/td>\n<td>Static pump pressure<\/td>\n<td> kPa<\/td>\n<td>140<\/td>\n<td>115<\/td>\n<td>150<\/td>\n<td>105<\/td>\n<\/tr>\n<tr>\n<td> Water jacket<\/td>\n<td>\u201dG<\/td>\n<td>1 1\/4&#8243;<\/td>\n<td>1 1\/4&#8243;<\/td>\n<td>1 1\/4&#8243;<\/td>\n<td>1 1\/4&#8243;<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Sound level (3)<\/td>\n<td>STD version (5)<\/td>\n<td>dB(A)<\/td>\n<td>51<\/td>\n<td>53<\/td>\n<td>53<\/td>\n<td>53<\/td>\n<\/tr>\n<tr>\n<td>MC version (5)<\/td>\n<td>dB(A)<\/td>\n<td>50<\/td>\n<td>52<\/td>\n<td>52<\/td>\n<td>52<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Weight<\/td>\n<td>Transport weight<\/td>\n<td>kg<\/td>\n<td>224<\/td>\n<td>239<\/td>\n<td>269<\/td>\n<td>283<\/td>\n<\/tr>\n<tr>\n<td>Operating weight<\/td>\n<td>kg<\/td>\n<td>229<\/td>\n<td>244<\/td>\n<td>275<\/td>\n<td>289<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Remarks:<\/strong><\/p>\n<ul>\n<li><strong>Cold water from 12 \u00b0 C to 7 \u00b0 C, outside temperature 35 \u00b0 C;<\/strong><\/li>\n<li><strong>Hot water from 40 to 45\u00b0C, outdoor temperature 7\u00b0C;<\/strong><\/li>\n<li><strong>Sound level measured at 1 m from the location of the unit according to ISO 3744;<\/strong><\/li>\n<li><strong>N.B. The weight of the WP version is specified in the technical documentation<\/strong><\/li>\n<\/ul>\n<h3>Dimensions<\/h3>\n<table class=\"tableStyle tableXSmall spacetable\">\n<tbody>\n<tr align=\"center\">\n<td rowspan=\"4\" width=\"16%\"><img loading=\"lazy\" decoding=\"async\" title=\"Air-cooled chiller CLINT, CHA\/K 91\u00f7151\" src=\"\/wp-content\/uploads\/2016\/12\/size-cww-1302b-lhp.png\" alt=\"Air-cooled chiller CLINT, CHA\/K 91\u00f7151\" width=\"100\" height=\"167\" border=\"0\"><\/td>\n<td colspan=\"3\" width=\"7%\">CHA\/IK\/\u0410<\/td>\n<td width=\"16%\">91<\/td>\n<td width=\"16%\">101<\/td>\n<td width=\"16%\">131<\/td>\n<td width=\"16 %\">151<\/td>\n<\/tr>\n<tr>\n<td>L<\/td>\n<td>STD<\/td>\n<td>mm<\/td>\n<td>1850<\/td>\n<td>1850<\/td>\n<td>1850<\/td>\n<td>1850<\/td>\n<\/tr>\n<tr>\n<td>W<\/td>\n<td>STD<\/td>\n<td>mm<\/td>\n<td>1000<\/td>\n<td>1000<\/td>\n<td>1000<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td>H<\/td>\n<td>STD<\/td>\n<td>mm<\/td>\n<td>1300<\/td>\n<td>1300<\/td>\n<td>1300<\/td>\n<td>1300<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 25px;\">Documents<\/span><\/p>\n<p><a href=\"\/wp-content\/uploads\/resource\/Catalog_Clint.pdf\">Product catalog for Clint chillers<\/a><\/p>\n<h3>Price list of chillers CLINT<\/h3>\n<a class=\"button green button_left button_size_3\" href=\"\/wp-content\/uploads\/resource\/Pricelist-chillers-91-151-clint.pdf\"     target=\"_blank\"    title=\"\"><span class=\"button_icon\"><i class=\"fa fa-file-pdf-o\"  aria-hidden=\"true\"><\/i><\/span><span class=\"button_label\">DOWNLOAD<\/span><\/a>\n\n","protected":false},"excerpt":{"rendered":"<h3>Air-cooled chiller chillers and heat pumps Clint<\/h3>\n<p>are equipped with an intelligent control system that makes it unnecessary to use a buffer tank. These are highly efficient chillers and heat pumps with quiet operation, optimized cost and size. The wide range of accessories for these chillers offers great variety and functionality of this series of aggregates. This chiller model comes with a different power output from 25 kW to 42 kW.<\/p>\n","protected":false},"featured_media":11284,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"pwb-brand":[1330],"product_brand":[],"product_cat":[765,763],"product_tag":[],"class_list":["post-15096","product","type-product","status-publish","has-post-thumbnail","pwb-brand-clint","product_cat-air-cooled-liquid-chillers","product_cat-chillers","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"brands":[{"id":1330,"name":"CLINT","slug":"clint"}],"_links":{"self":[{"href":"https:\/\/bgr.bg\/en\/wp-json\/wp\/v2\/product\/15096","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bgr.bg\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/bgr.bg\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/bgr.bg\/en\/wp-json\/wp\/v2\/comments?post=15096"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bgr.bg\/en\/wp-json\/wp\/v2\/media\/11284"}],"wp:attachment":[{"href":"https:\/\/bgr.bg\/en\/wp-json\/wp\/v2\/media?parent=15096"}],"wp:term":[{"taxonomy":"pwb-brand","embeddable":true,"href":"https:\/\/bgr.bg\/en\/wp-json\/wp\/v2\/pwb-brand?post=15096"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/bgr.bg\/en\/wp-json\/wp\/v2\/product_brand?post=15096"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/bgr.bg\/en\/wp-json\/wp\/v2\/product_cat?post=15096"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/bgr.bg\/en\/wp-json\/wp\/v2\/product_tag?post=15096"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}