Air-cooled chillers CLINT CHA/K 182-P ÷ 604-P
Air cooled chillers with pump group and AQUALOGIK control from 47 kW to 178 kW
Air-cooled Clint chillers are used in combination with fan convectors in industrial processes. These chillers and heat pumps are equipped with axial fans, helical compressor and plate heat exchanger even in the super silent version, the units can be equipped with a hydraulic module with a buffer tank, a circulator pump or a buffer tank and a pump. The CHA/K Series Clint chilers and heat pumps have an intelligent control system. A wide range of accessories is available to all chillers and heat pumps.
| Power (Model): | 47 – 178 kW (Aqua Plus) |
|---|---|
| Type: | Air – Water |
Chillers and heat pumps CHA/K 182-P÷604-P AQUAPLUS
are charged with the environmental freon R410A and are designed to meet the needs of the service and industrial sectors.
They are used in combination with fan coil units for room air conditioning or cooling in industrial processes. The units can be delivered with the RS 485 ModBus module for connection to the innovative control and control system CLIMAFRIEND. It allows you to program up to 30 different values to achieve a high level of comfort and efficiency without compromise.
These chillers and heat pumps are equipped with axial fans, helical compressor and plate heat exchanger even in the super silent version, the units can be equipped with a hydraulic module with a buffer tank, a circulator pump or a buffer tank and a pump.
Chillers and heat pumps of the CHA/K 182 ÷ 604 series AQUALIGHT with AQUALOGIK technology
are equipped with an intelligent control system that optimizes the inverter pump’s operating point and modulates the fan’s power supply, making it unnecessary to use a buffer tank. This results in high efficiency, quiet operation, optimized cost and size.
Other advantages of Clint chillers are:
The wide range of accessories available separately offers an extremely versatile and functional range of this series of units.
-
Self-supporting frame made of galvanized sheet metal, protected with powder coating;
-
Spiral compressor with monitor glass, with built-in thermal protection in compressor and heater heater, if required;
-
Axial fans directly copied to the external rotor of the engine;
-
Condenser made of copper tubes, ribbed with aluminum lamellae;
-
AISI 316 stainless steel evaporator (solder type): with one refrigerant circuit and one water circuit for models 182-P ÷ 453-P; with two independent refrigeration circuits and one water circuit for the 524-P ÷ 604-P models, fitted with a pressure switch, an anti-freeze heater is installed for the heat pump version;
-
Freon R410A;
-
The electrical panel includes: main switch with automatic door locking, fuses, overload protection of the compressor and fan heaters;
-
Microprocessor control and regulation system;
-
The water circuit includes: a circulator pump, a circulator pump with an inverter (for ST version), a buffer tank, a safety valve, manometers and an expansion vessel;
-
Electronic proportional devices to reduce the noise level with the continuously adjustable fan speed. This also allows the unit to operate at -20°C outside (for ST version);
Technical data
| CHA/K | 182-P | 202-P | 242-P | 262-P | 302-P | 363-P | 393-P | 453-P | 524-P | 604-P | ||
| Cooling | Cooling power (1) |
kW | 47.6 | 54.9 | 63.5 | 72.9 | 83.4 | 95.9 | 110.4 | 126.8 | 147.7 | 177.8 |
| Consum. energy (1) | kW | 16.1 | 18.8 | 21.8 | 25.0 | 28.3 | 31.6 | 37.9 | 43.3 | 50.1 | 58.2 | |
| Heating | Heating power (2) | kW | 54.1 | 61.8 | 71.4 | 80.3 | 90.4 | 105.5 | 120.2 | 134.9 | 154.3 | 187.0 |
| Consum. energy (2) | kW | 17.3 | 19.6 | 23.1 | 25.4 | 28.8 | 33.4 | 38.5 | 43.8 | 50.5 | 60.4 | |
| Compressor | Number | n° | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 4 | 4 |
| Type | Spiral | |||||||||||
| Refrigeration circuit | n° | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | |
| Steps | n° | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 4 | 4 | |
| Evaporator | Water flow | l/s | 2.27 | 2.62 | 3.03 | 3.48 | 3.98 | 4.58 | 5.27 | 6.06 | 7.04 | 8.49 |
| Loss of pressure | kPa | 45 | 48 | 43 | 48 | 43 | 58 | 46 | 53 | 48 | 48 | |
| Pipe connection | “G | 1 1/2″ | 1 1/2″ | 1 1/2″ | 1 1/2″ | 1 1/2″ | 2 1/2″ | 2 1/2″ | 2 1/2″ | 2 1/2″ | 2 1/2″ | |
| Electrical characteristics | Power supply | V/Ph/Hz | 400/3+N/50 | |||||||||
| Max. Operating current | A | 40 | 43 | 52 | 56 | 65 | 75 | 85 | 103 | 111 | 133 | |
| Max. Starting current | A | 163 | 165 | 175 | 188 | 232 | 199 | 218 | 265 | 243 | 300 | |
| Standard and quiet version | Fan | n° | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 |
| Air flow | m3/s | 4.8 | 4.7 | 7.1 | 7.1 | 7.3 | 7.1 | 9.7 | 9.7 | 11.4 | 15.0 | |
| STD Sound Level (3) | dB(A) | 56 | 56 | 60 | 60 | 60 | 60 | 60 | 61 | 61 | 61 | |
| Sound level SL (3) | dB(A) | 54 | 54 | 58 | 58 | 58 | 58 | 59 | 59 | 59 | 59 | |
| Super quiet version | Fan | n° | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | |
| Air flow | m3/s | 4.1 | 3.9 | 5.7 | 5.7 | 6.0 | 7.7 | 9.2 | 8.9 | 11.8 | ||
| Sound level (3) |
dB(A) | 52 | 52 | 56 | 56 | 56 | 55 | 55 | 55 | 56 | ||
| Pump unit and buffer tank | Power consumed by the pump | kW | 0.75 | 0.75 | 0.75 | 0.75 | 1.10 | 1.50 | 1.50 | 1.50 | 1.50 | 1.85 |
| Static pump pressure | kPa | 120 | 110 | 110 | 110 | 140 | 150 | 140 | 120 | 110 | 100 | |
| Volume of the buffer tank | L | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 600 | 600 | |
| Expansion tank | L | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 18 | 18 | |
| Water jacket | ”G | 2 1/2″ | 2 1/2″ | 2 1/2″ | 2 1/2″ | 2 1/2″ | 2 1/2″ | 2 1/2″ | 2 1/2″ | 2 1/2″ | 2 1/2″ | |
| Weight | Shipping weight (4) | kg | 595 | 624 | 663 | 682 | 791 | 878 | 927 | 1036 | 1135 | 1374 |
| Shipping weight (5) | kg | 745 | 774 | 813 | 832 | 941 | 1033 | 1082 | 1191 | 1375 | 1614 | |
| Shipping weight (4) |
kg | 600 | 630 | 670 | 690 | 800 | 890 | 940 | 1050 | 1150 | 1390 | |
| Shipping weight (5) |
kg | 1145 | 1174 | 1213 | 1232 | 1341 | 1433 | 1482 | 1591 | 1975 | 2214 | |
Remarks:
- Cold water from 12 ° C to 7 ° C, outside temperature 35 ° C;
- Hot water from 40 to 45°C, outdoor temperature 7°C;
- Sound level measured at 1 m from the location of the unit according to ISO 3744;
- A unit without buffer and pump;
- A buffer and a pump unit;
- N.B. The weight of the WP version is specified in the technical documentation
Dimensions
![]() |
CHA/K | 182-P | 202-P | 242-P | 262-P | 302-P | 363-P | 393-P | 453-P | 524-P | 604-P | ||
| L | STD | mm | 2350 | 2350 | 2350 | 2350 | 2350 | 2350 | 2350 | 2350 | 3550 | 3550 | |
| SSL | mm | 2350 | 2350 | 2350 | 2350 | 2350 | 2350 | 3550 | 3550 | 3550 | |||
| P | STD | mm | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | |
| SSL | mm | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | |||
| H | STD | mm | 1920 | 1920 | 1920 | 1920 | 2220 | 2220 | 2220 | 2220 | 2220 | 2220 | |
| SSL | mm | 2220 | 2220 | 2220 | 2220 | 2220 | 2220 | 2220 | 2220 | 2220 | 2220 |
![]() |
CHA/K 182-P ÷ 604-P | ||
| A | mm | 300 | |
| B | mm | 1800 | |
| C (*) | mm | 800 | |
| D | mm | 800 | |
Remarks:
- (*) Electrical panel on side C;
Documents
Product catalog for Clint chillers