BLACK FRIDAYInverter air-water heat pump Crystal Aqua Aura II 6S, 6 kW

Inverter air-water heat pump Crystal Aqua Aura II 6S

is from the Aqua Aura II series of Crystal. This series of heat pumps comes into the market after a series of trials made in the northern countries under very severe weather conditions. Every detail in this air-to-water heat pump is selected to provide precise and reliable operation under all conditions.

Tag: Categories: , SKU: Aqua Aura II 6S
Original price was: 4 039.21 €.Current price is: 3 299.00 €. VAT included
Inverter air-water heat pump Crystal Aqua Aura II 6S, 6 kW цена - Heat pumps | BGR Group
Buy withtbi bank logo
13 x €281.09
12 ВНОСКИ
307.91 евро
Кредитен калкулатор UNI Credit 1.4.0
Само няколко клика до желаната покупка от 75 евро до 25 000 евро:

1. Добавете желания от Вас продукт в кошницата.

2. В меню "Метод на плащане" изберете "На кредит с УниКредит Кънсюмър Файненсинг".

3. Изберете брой месечни вноски, според Вашите възможности и предпочитания.

4. Завършете кандидатстването изцяло дигитално или очаквайте телефонно обаждане.

Цена на артикула
3299.00 евро
Брой месеци за погасяване *
Размер на погасителна вноска
. евро
ГЛП
%
ГПР
%
* Срокът на изплащане се заявява при приключване на поръчката.
Откажи
Добавете в количката

Inverter air-water heat pump Crystal Aqua Aura II 6S, 6 kW

Aqua Aura Crystal air-to-water inverter heat pump  Aqua Aura Crystal air-to-water inverter heat pump  Aqua Aura Crystal air-to-water inverter heat pump Aqua Aura Crystal air-to-water inverter heat pump

Functional characteristics:

EcoTouch control

Inverter air-to-water heat pump Aqua Aura Crystal;The touchscreen 4.3 inch LCD Touchscreen allows easy and intuitive control and tuning of the many components of the heating system. The advanced software algorithm provides high-performance operation of the heat pump system at minimal energy costs. The ability to integrate a WiFi module into the management allows remote access and control of the entire system.

Temperature curve management

Inverter air-to-water heat pump Aqua Aura Crystal;Users are given the opportunity to adjust the system to meet the requirements in each specific case – variable heat load, different insulation, joinery, etc. , building their own temperature curve. It is created as an inverse linear characteristic between the outdoor temperature (five values) and the leaving water temperature (five values ​​at each set outdoor temperature).

Information about the current state of the system

Not only installers but also users can monitor the current status and operating parameters such as frequency and power of the compressor current, water flow, all temperatures, high and low pressures, etc. by means of a graphical display.

Room temperature control

Inverter air-to-water heat pump Aqua Aura Crystal;

In addition to the temperature control of the exhaust coil, consumers can also choose to run at room temperature. In this mode, the heat pump will calculate the water supply temperature so that it can quickly achieve and maintain the set room temperature.

Absence mode (holiday mode)

Inverter air-to-water heat pump Aqua Aura Crystal;The built-in logic of the absence mode allows users to set the start and end time of the vacation, during which the heat pump will keep a lower temperature in the dwelling and the DHW cylinder / domestic hot water /, thus consumes less energy. The system will switch back to normal mode of operation shortly before the end of the vacation and users will go to a well-warmed home with a preheated boiler.

Automatically switch to Heating / Cooling modes

Inverter air-to-water heat pump Aqua Aura Crystal;

Automatic switching between heating and cooling based on outside temperature, room temperature or external signal from a peripheral device is allowed, thus minimizing user interference.

Other functions of the air-to-water heat pump Crystal Aqua Aura II 6S:

  • Compensation at room temperature
  • Sleep Mode
  • Double temperature curve
  • Avoid peak (peak) tariffs
  • DHW production
  • Anti-Legionella Program
  • Function in the presence of a minor error
  • Modification of the software

Technical advantages of the heat pump

  • 4.3 “touch screen ECO Touch with menu in Bulgarian, advanced software algorithm for high efficiency operation of the heat pump
  • Temperature curve control, room temperature or fixed water temperature
  • Control of circulating pumps for heating and DHW
  • External heat source control via priority relay
  • Reflection of the refrigeration process through multiple temperature sensors and pressure sensors
  • Hydraulic contour preview (temperature sensors, key flow)
  • Microprocessor control
  • 2 temperature zones – low temperature and high temperature
  • Quiet operation mode
  • Easy installation and service

Price advantages of the heat pump

  • Built-in 3-way valve for DHW
  • Built-in electric heater with priority option (2 steps – 2 kW or 6 kW)
  • WiFi module for remote access and control of the heating system
  • 5 temperature sensors for controlling hydraulic circuits

Technical parameters

Model Aqua Aura II 6S Aqua Aura II 9S Aqua Aura II 12S Aqua Aura II 15S Aqua Aura II 19S
Energy efficiency class – low temperature application (W35) А+++ А+++ А+++ А+++ А+++
SCOP, temperate climate zone, (Tvoda=+35°С) 4.74 4.73 4.71 4.99 4.84
Seasonal heating energy efficiency (ηs,h) % 186.7 186 185.5 196.8 190.5
Power supply V/Hz/Ph 220-240/50/1 220-240/50/1 220-240/50/1 380-420/50/3 380-420/50/3
Heating capacity (W35˚C @ A7˚C) kW 6.5 9.2 11.6 15.35 18.5
C.O.P min/max W/W 4.5/4.7 4.38/4.71 4.3/4.9 4.78/5.06 4.47/5.01
Heating capacity min/max. (W35˚C @ A7˚C) kW 3.5/6.5 4.3/9.2 5.5/11.6 6/15.35 9.2/18.5
Power supply min/max (W35˚C @ A7˚C) kW 0.758/1.41 0.927/2.097 1.107/2.683 1.222/3.209 1.834/4.142
Heating capacity (W45˚C @ A7˚C) kW 6 8.6 11.2 14.26 18.2
C.O.P min/max W/W 3.34/3.56 3.37 / 3.58 3.30 / 3.50 3.64 / 3.82 3.60 / 3.82
Heating capacity min/max. kW 3.15/6 3.9/8.6 4.9/11.2 5.6/14.26 8.5/18.2
Power supply min/max kW 0.943/1.732 1.162/2.550 1.401/3.263 1.551/3.913 2.248/4.998
Cooling power (W18˚C @ A35˚C) kW 7.45 9.5 9.8 18.57 22.5
E.E.R min/max W/W 4.05/4.45 4.0/4.6 3.8 / 4.0 3.78 / 5.42 3.58 / 5.12
Cooling capacity min/max kW 6.22/7.45 6.7/9.5 7.2 / 9.8 7.23 / 18.57 8.5 / 22.5
Power supply min/max kW 1.4/1.863 1.679/2.242 1.791 / 2.510 1.334/4.917 1.660 / 6.285
Cooling power (W7˚C @ A35˚C) kW 4.5 7.2 8.5 13 16
E.E.R min/max W/W 2.5/2.74 2.8/3.1 2.6/3.5 2.96/3.29 2.85/3.2
Cooling capacity min/max kW 3.5/4.5 4.9/7.2 4.9/8.5 4.46/13 5.5.2016
Power supply min/max kW 1.33/1.68 1.452/2.366 1.358/2.987 2.592/4.390 2.97/5.51
Temperature range Heating / Cooling ˚C -25 ~ 43 -25 ~ 43 -25 ~ 43 -25 ~ 43 -25 ~ 43
Minimum temperature in the system Heating / Cooling ˚C 20/7 20/7 20/7 20/7 20/7
Compressor Type – Twin DC Rotary Twin DC Rotary Twin DC Rotary Twin DC Rotary Twin DC Rotary
Fan Number – 1 1 1 2 2
Debit m3/h 2500 3150 3150 6200 7000
Power supply W 34 45 45 90 120
Noise Indoor/outdoor dB(A) 44/52 44/53 44/52 44/59 44/59
Heat exchanger Type – Platelets Platelets Platelets Platelets Platelets
Pressure drop kPa 26 26 26 26 26
Pipe connections Inch G1’’ G1’’ G1’’ G1-1/4’’ G1-1/4’’
Expansion tank L 5 5 5 5 5
Circulating pump Type – DC, PWM DC, PWM DC, PWM DC, PWM DC, PWM
Effort, max. mH2O 7.5 9 9 12.5 12.5
Flow – Min./Nom./Max. l/s 0.21/0.29/0.35 0.26/0.43/0.52 0.34/0.57/0.68 0.43/0.71/0.85 0.55/0.92/1.1
Overall dimensions / packaging WxDxH Indoor unit mm 500×300х750/

580×350х820

500×300х750/

580×350х820

500×300х750/

580×350х820

500×300х750/

580×350х820

500×300х750/

580×350х820

Outdoor unit mm 1010x370x700/

1075x480x870

1165x370x850/

1230x480x1020

1165x370x850/

1230x480x1020

1085x400x1450/

1140x460x1590

1085x400x1450/

1140x460x1590

Refrigerant Type / quantity kg R32 / 1.1 R32 / 1.6 R32 / 1.8 R32 / 2.6 R32 / 3.0
Extra freon >​​ 5m g/m 30 30 30 30 30
Extra compr. oil g/m according to manual according to manual according to manual according to manual according to manual
Pipe connections Liquid – gas inch 3/8” – 5/8” 3/8” – 5/8” 3/8” – 5/8” 3/8” – 3/4” 3/8” – 3/4”
Maximum length m 20 20 20 20 20
Net weight Internal / outdoor unit kg 37 / 65 39 / 75 39 / 79 42 /110 42 / 120

User’s Guide

Catalogue

Product sheet

Price list

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

✕