Air-cooled chillers CLINT CHA/IK/A 172-P ÷ 574-P

Air-cooled chillers CLINT CHA/IK/A 172-P ÷ 574-P

are of Energy Class A and are designed to meet the needs of medium-sized businesses. They are used in conjunction with terminal devices for room air conditioning or heat removal. Air cooled chillers are equipped with axial fans, inverter helical compressors, condenser heat exchangers with micro-channels and plate heat exchangers, even in the super silent version.

The series includes air-cooled water cooling units from 50 kW to 179 kW

air cooled chillers air cooled chillers air cooled chillers air cooled chillers air cooled chillers air cooled chillers air cooled chillers

Power (Model): 47 – 178 kW (Aqua Plus)
Type: Air – Water

Categories: , SKU: CHA/IK/A 172-P ÷ 574-P
Air-cooled chillers CLINT CHA/IK/A 172-P ÷ 574-P цена - Chillers | BGR Group
Send an inquiry

Air-cooled chillers CLINT CHA/IK/A 172-P-574-P

are of Energy Class A and are designed to meet the needs of medium sized businesses in the service and manufacturing sectors.

They are used in combination with terminal devices, for air-conditioning of premises or the removal of heat generated by manufacturing processes. They can be equipped with a RS 485 Modbus connection that ensures optimal energy efficiency and comfort.

Chillers are equipped with axial fans, inverter helical compressors, condenser heat exchangers with micro-channels and plate heat exchangers, even in the super silent version. Micro-channel condenser heat exchangers provide high energy efficiency (high EER), and inverter control of the compressor ensures high efficiency in partial loads (ESEER-IPLV). The possibility of inverter control of the circulation pump and fans, as well as a number of additional accessories, adds even more to the advantages of the series.

Advantages of air-cooled chillers CLINT CHA/IK/A 172-P-574-P

  • Structure with galvanized sheet frame with polyester powder coating;
  • Inverter helical and ON-OFF helical compressors with oil level sight, built-in thermal protection in compressor and heater;
  • Axial fans directly copied to the external rotor of the engine;
  • Aluminum condenser with microchannels;
  • AISI 316 stainless steel evaporator (spliced type) with one refrigeration and one water circuit in models 192-P ÷ 472-P; with two independent refrigeration circuits and one water in models 534-P ÷ 634-P, equipped with a pressostat;
  • Electronic TRV;
  • Freon 410А;
  • The electrical panel includes: main switch with automatic door locking, fuses, overload protection of the compressors and fan contactor;
  • Electronic proportional noise reduction devices with continuous fan speed control. This also allows the unit to function when cooling down to -20°C outside;
  • Microprocessor and control system;

Technical data

CHA/IK/A 172-P 192-P 212-P 232-P 272-P 303-P 352-P 372-P 484-P 574-P
Cooling Cooling
power (1)
kW 49.9 57.7 65.7 74.8 85.9 97.7 112.0 130.0 152.0 179.0
Consum. energy (1) kW 15.4 17.9 20.2 23.4 26.7 30.0 34.7 40.1 46.7 55.0
EER (1) 3.24 3.22 3.25 3.20 3.22 3.26 3.23 3.24 3.25 3.25
Cooling (EN14511) Cooling
power (1)
kW 49.6 57.4 65.4 74.4 85.4 97.2 112.0 129.0 151.0 178.0
Consum. energy (1) kW 15.7 18.2 20.5 23.8 27.2 30.5 35.2 40.7 47.3 55.6
EER (1) 3.16 3.15 3.19 3.13 3.14 3.19 3.18 3.17 3.19 3.20
Compressor Number n° 2 2 2 2 2 2 2 2 4 4
Cooling circles n° 1 1 1 1 1 1 1 1 2 2
Steps Straightforward
Evaporator Water flow l/s 2.38 2.76 3.14 3.57 4.10 4.67 5.35 6.21 7.26 8.55
Loss of pressure kPa 41 40 32 39 47 40 35 44 33 30
Pipe connection “G 1 1/2″ 1 1/2″ 2 1/2″ 2 1/2″ 2 1/2″ 2 1/2″ 2 1/2″ 2 1/2″ 2 1/2″ 2 1/2″
Electrical characteristics Power supply V/Ph/Hz 400/3/50
Max. Operating current A 38 43 48 54 64 71 81 88 113 132
Max. Starting current A 109 109 154 157 164 214 193 193 227 275
With a pump Static pump pressure kPa 130 120 120 105 125 160 150 125 105 115
Water jacket ”G 2″1/2 2″1/2 2″1/2 2″1/2 2″1/2 2″1/2 2″1/2 2″1/2 2″1/2 2″1/2
Sound level STD (2) dB(A) 57 57 61 61 61 61 62 62 62 62
Low noise version dB(A) 55 55 59 59 59 59 60 60 60 60
Super quiet version dB(A) 53 53 57 57 56 56 57 57
Weight Transport weight kg 584 653 712 721 730 817 1036 1045 1379 1424
Shipping
weight
kg 590 660 720 730 740 830 1050 1060 1400 1450

Remarks:

  • Cold water from 12 ° C to 7 ° C, outside temperature 35 ° C;
  • Sound level measured at 1 m from the location of the unit according to ISO 3744;
  • N.B. The weight of the SSL version is specified in the technical documentation

Dimensions

CHA/IK/A 172-P 192-P 212-P 232-P 272-P 302-P 352-P 372-P 484-P 574-P
L STD mm 2350 2350 2350 2350 2350 3550 3550 3550 4700 4700
SSL mm 2350 2350 2350 3550 3550 3550 4700 4700
P STD mm 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
H STD mm 1920 2220 2220 2220 2220 1920 2220 2220 2220 2220
SSL mm 1920 2220 2220 1920 1920 2220 2220 2220
Air-cooled chillers CLINT CHA/IK/A 172-P ÷ 574-P CHA/IK/A 172-P ÷ 574-P
A mm 300
B mm 1800
C mm 800
D mm 800